Skip to content Skip to sidebar Skip to footer
warning: this is not how to include the shop layout in a page, please read docs

Preview

Filtering byΚατηγορίες προϊόντωνfood-microbiology Clear filters



How to install

You can now add layouts you create in the Shop Admin into any post or page. To make it simple a Shortcode Generator is included. You can access it via this button.

The first button is the shortcode generator launcher and the second one ( the one with a plus ) ads a single audio player to the page from the media gallery.

MenidiMedica

ΙΑΤΡΙΚΟΣ ΕΞΟΠΛΙΣΜΟΣ ΑΝΑΛΩΣΙΜΑ - ΜΕΝΙΔΙ, ΑΙΤΩΛΟΑΚΑΡΝΑΝΙΑ
Η έμπειρη και αφοσιωμένη ομάδα μας εστιάζει όλη της την ενέργεια για να προσφέρει αυτό που ζητούν οι πελάτες μας σε πολύ ανταγωνιστικές τιμές, διασφαλίζοντας την επιτυχία της επιχείρησής σας.

Διεύθυνση
Μενίδι Αιτωλίας & Ακαρνανίας
ΤΚ: 30016, Ελλάδα

Υποστηριξη πελατων

T +30 2681088000
Μ +30 6937115868
Μ +30 6976292146
menidimedica@gmail.com

Business Hours
From Monday through Friday
08:00 – 17:00 (EET)

ΠΛΗΡΟΦΟΡΙΕΣ
ΒΡΕΙΤΕ ΜΑΣ
MenidiMedica © 2009 – 2025. All Rights Reserved.

Monocyto-ID Listeria Scan

Standard method for biochemical detection and identification of Listeria monocytogenes Description Listeriosis is a serious infection, classified as a zoonosis, which results from the ingestion of food contaminated with the bacterium Listeria monocytogenes. It leads to a severe clinical picture in infants, immunocompromised individuals and poses significant risks to foetuses, while pregnant women usually have mild symptoms. Contents FX100025 - 25 vials R FX100100 - 100 vials R Note: All kit components are stable until the expiration date on the label. Protect them from light and contamination during use. Do not use the reagents after the expiration date. Store reagents at 2-8°C. Shelf life: 12 months from date of production Storage and stability: 2-8°C Samples Food, milk, dairy products, fish Note: for sample preparation, please contact the scientific support department of MenidiMedica Biotech Procedure - Incubation of the sample in suitable nutrient medium (e.g. Ottaviani Agosti Agar Base) for 24 hours at 37⁰C in an incubator - Place a vial - found on the package - with the Listeria monocytogenes biochemical detection and identification reagent in the incubator at the same time as the incubation described in step a is performed. - Remove the medium and the vial from the incubator. - Open the vial and add one drop or 50 ul of deionised water to the vial - Collect a formed colony from the nutrient medium with a swab and dip it into the vial, shaking gently until the contents of the swab are dissolved in the vial. - Incubate the vial in the incubator at 37⁰C for 6 hours - Remove the vial from the incubator and check the colour that has appeared Interpretation Green: positive sample for Listeria monocytogenes Sensitivity: 100% for Listeria monocytogenes Specificity: 100% for Listeria monocytogenes A comparison study with other methods was performed on a total number of samples n=500. Monocyto-ID Listeria Scan PDF ENG

Mastigal Check

Mastitis Quantitative Test for reproductive animals Description Mastitis is the persistent, inflammatory reaction of the udder tissue due to physical trauma or microorganisms infections. Mastitis, a potentially fatal mammary gland infection, is the most common disease in dairy cattle worldwide. It is also the most costly disease to the dairy industry. Milk from reproductive animals suffering from mastitis has an increased somatic cell count. Test Principle Mastitis increases the permeability between the blood and milk compartments, resulting in extravasation of plasma proteins into the milk. Due to this, the colorimetric measurement of these proteins is equivalent to the degree of inflammation of the udder with quantitative results. The advantages of the method are: 1. The current method detects the presence of a blood protein in milk as a good indicator of ongoing inflammation. So, it can detect even early phases of mastitis occurrence precisely. 2. The test results are not influenced by the lactation or the seasonal variations. Kit presentation 100 tests: R1 - 20 mL., R2 - 0.04 mL., R2 dilution - 8 mL., R3 - 8 mL. (82072-100) 500 tests: R1 - 5 x 20 mL., R2 - 0.2 mL., R2 dilution - 2 x 20 mL., R3 - 2 x 20 mL. (82072-500) 1000 tests: R1 - 10 x 20 mL., R2 - 0.4 mL., R2 dilution - 4 x 20 mL., R3 - 4 x 20 mL. (82072-1000) Reagent Composition and Preparation R1 - Lysis reagent R2 - Concentrated agglutination reagent R2 dilution - Diluent for R2 R3 - Chromogen reagent WR2 preparation: Mix R2 with R2 dilution at a ratio 1:200. Always, prepare fresh WR2. It is stable for 24 hours. Stability 24 months at 2-8°C. All the components of the kit are stable until the expiration date on the label. Protect them from light and contaminations during their use. Do not use reagents over the expiration date. Store the reagents at 2-8°C Samples: Raw milk from different reproductive animals Sample preparation Mix 0.2 mL. of R1 with 0.1 mL. of raw milk, mix and incubate at RT for 30 minutes. After that, centrifuge at 10.000g x 1' (using a microcentrifuge) Procedure Collect 80 uL. of supernatant from the centrifuged tube, add 80 uL. WR2 and 80 uL. of R3. Mix, incubate for 180 minutes and read in Electra m2 Unified Analyzer choosing the parameter MASTQT or in a microplate reader at 405 nm. Application sheets are available for all the commercial spectrophotometers and microplate readers. Ask MenidiMedica or our exclusive representatives for details. *Blank = reagent blank MASTIGAL CHECK

Salmonellix - Salmonella Detection Kit

Ensure Safety in Every Bite Salmonella, a prevalent yet hazardous bacterium, is found on a multitude of surfaces and in a wide variety of foods, such as chicken, beef, pork, eggs, fruits, vegetables, and processed goods. Consuming this pathogen can result in severe health complications, including diarrhea, stomach pain, fever, nausea, and vomiting. Dedicated to enhancing public health and safety, we proudly present the Salmonella Detection Kit, commercially known as Salmonellix. This innovative solution is specifically designed for the efficient detection of Salmonella spp. directly from surfaces, thus protecting consumers and businesses alike. Potential Business Applications for Salmonellix: Salmonellix is an indispensable tool for various businesses and facilities, ensuring food safety and environmental health. Its applications span across Food Processing Plants, Restaurants and Catering Services, Agricultural Operations, Grocery Stores, Supermarkets, Educational Institutions, Childcare Centers, Hospitals, Healthcare Facilities, Food Safety Laboratories, Public Health Departments. By incorporating Salmonellix into their safety and hygiene protocols, they can significantly reduce the risk of Salmonella outbreaks, ensuring the health of their clientele and compliance with health regulations. Eradicate the Threat of Salmonella from Every Surface Innovative Detection Technology The Salmonellix kit embodies cutting-edge microbiological advancements, featuring a selective and differential medium that isolates and identifies Salmonella spp. with precision. This comprehensive kit is your frontline defense against contamination, ensuring the highest standards of hygiene and safety. What’s Inside the Kit? Each Salmonellix kit includes: - 30 Sealed Detection Units: Each unit comprises a sterile swab paired with a culture medium tube. - Comprehensive Instruction Sheet: Detailed, step-by-step guidance to ensure accurate sampling and result interpretation. - 30 sterile physiological solutions Simplified Testing Procedure 1. Prepare: Extract the sterile swab from its protective envelope. 2. Moisten: Dip the swab into sterile physiological solution to activate. 3. Sample: Swipe the swab across a 10cm x 10cm area in both horizontal and vertical motions. 4. Cultivate: Insert the swab into the tube with the culture medium. 5. Incubate: Secure the tube and incubate at 37°C for 18-24 hours for optimal growth. Interpreting Your Results - Red: Celebrate a clean bill of health with no Salmonella spp. detected. - Red/Black: Presence of Salmonella spp., indicating contamination. - Yellow/Black: Detection of Citrobacter spp., another indicator of microbial presence. Uncompromised Quality Every batch of the Salmonellix undergoes rigorous quality control against benchmark strains, including Salmonella typhimurium and Citrobacterfreundii, ensuring reliability and accuracy in every test. Storage and Precautions Designed for ease of use and longevity, the kit is stored ideally between 10-25°C, shielded from light. Our commitment to safety extends to our users, recommending only trained professionals handle the testing process, supported by a detailed safety data sheet for comprehensive understanding and adherence. Backed by Global Standards Our kit not only meets but exceeds international microbiological testing standards, aligning with ISO 18593 and ISO 17604 guidelines, for sampling techniques and carcass sampling for microbiological analysis, respectively. Your Safety, Our Priority With the Salmonellix kit, protect your environment, your products, and most importantly, your health. Equip your team with the tools to detect and act against Salmonella contamination, ensuring a safer tomorrow. SALMONELLIX ENG PDF
el